Humidity Controller - The Protector

In stock
0.00
(0 reviews) Write a review
$11220
Request Bulk Order Quote Chat Now

The INNO-HUMCTRL is a digital humidity controller equipped with a 15-foot sensor. It boasts an accurate humidity sensor and a photocell for day and night adjustments. This unit can effectively manage humidifying or dehumidifying devices, offering separate settings for day and night humidity levels.

  • Max Amp: 10 Amps at 120V AC, 60Hz
  • DAY Humidity Setting: Adjustable from 15% to 90% rH
  • NIGHT Humidity Setting: Adjustable from 15% to 90% rH
  • Humidity Dead-Band (Hysteresis): 5% rH
  • Sensor Cord Length: 15 ft
  • Weight: 2 lbs
  • Dimensions: 7.6” x 3.8” x 3.6”
  • For indoor use only
  • Operating temperature: 50°F to 95°F
  • Maximum relative humidity: 95>

Tell us what you need

+
Humidity Controller - The Protector
In stock
0.00
(0 reviews) Write a review

Description

The INNO-HUMCTRL is a digital humidity controller featuring a 15-foot sensor, precise humidity control, and a photocell for day and night adjustments. It can manage both humidifying and dehumidifying devices, with separate settings for day and night humidity levels.

COMPATIBILITY
This controller is compatible with all the humidifiers and dehumidifiers listed. Please contact us for any product-related inquiries.

FEATURES
Dehumidify Mode: If the set-point is 80% rH and the humidity exceeds 80% rH, the dehumidifier will activate until it lowers the humidity to 75% rH.
Humidify Mode: If the set-point is 80% rH and the actual humidity is below 80% rH, the humidifier will activate until it raises the humidity to 85% rH.
Humidify/Dehumidify Mode: Press and hold the knob for 3 seconds, then turn to select either Humidify or Dehumidify mode. Press the knob again to save the set point, indicated by a lit LED. Click the knob to display "day," then press and turn to set the day humidity level. Press again to enter the night humidity setting, indicated by "night" on the display. Turn to set and save the setting with another press.
Day mode: The controller is active only when the photocell detects light in the grow space.
24 hours: The controller is active both day and night.
Night mode: The controller is active only when the photocell detects darkness in the grow space.
Output: LED indicates when the output is active.

SPECIFICATIONS
Max Amp: 10 Amps at 120V AC, 60Hz
DAY Humidity Setting: Adjustable from 15% to 90% RH
NIGHT Humidity Setting: Adjustable from 15% to 90% RH
Humidity Dead-Band (Hysteresis): 5% RH
Sensor Cord Length: 15 ft
Weight: 2 lbs
Dimensions: 7.6” x 3.8” x 3.6”
For indoor use only
Operating temperature: 50°F to 95°F
Maximum relative humidity: 95%

FACTOR SETTINGS
Day Humidity Factory setting: 50% RH
Night Humidity Factory setting: 50% RH
Humidity Mode Factory setting: Dehumidify

Key Features

Accurate Humidity Control

The INNO-HUMCTRL boasts an accurate humidity sensor that ensures precise monitoring and control of humidity levels. The device allows for separate settings for day and night humidity, ensuring your indoor environment remains comfortable and conducive to plant growth or other humidity-sensitive applications.

Day and Night Adjustments

The integrated photocell lets the controller differentiate between day and night, allowing for customized humidity settings for each period. This feature is handy for growing spaces, where different humidity levels may be required during the light and dark phases.

Versatile Operation Modes

The INNO-HUMCTRL offers both humidifying and dehumidifying modes:

  • Dehumidify Mode: Activates the dehumidifier when the humidity exceeds the set point, reducing humidity until it reaches the desired level.
  • Humidify Mode: Activates the humidifier when the humidity falls below the set point, increasing humidity until it reaches the desired level.

Easy-to-Use Interface

The controller features a user-friendly interface with a simple knob for setting the desired humidity levels. The LED indicators provide clear feedback, showing when the output is active and which mode (day or night) is being adjusted.

Benefits of Using

Optimal Humidity Management

By providing precise control over humidity levels, the INNO-HUMCTRL helps create an ideal environment for plants, preventing excessive dryness or moisture issues. This ensures healthier plant growth and maximizes yield in grow spaces.

Energy Efficiency

Setting different humidity levels for day and night helps conserve energy by ensuring that humidifiers and dehumidifiers only operate when necessary. This targeted operation reduces unnecessary energy consumption and extends the life of your devices.

Versatility

The INNO-HUMCTRL is compatible with various humidifying and dehumidifying devices, making it a versatile solution for multiple applications, from horticulture to maintaining comfort in residential and commercial spaces.

Easy Installation and Setup

With a 15-foot sensor cord, the INNO-HUMCTRL offers flexibility in placement, allowing you to position the sensor in the optimal location for accurate readings. The straightforward setup process and clear instructions make starting and ensuring effective humidity control easy.

Usage Guidelines

Setting Up

  1. Mounting: Install the INNO-HUMCTRL in a suitable indoor location, ensuring it is within reach of a power source and the devices it will control.
  2. Connecting Devices: Plug your humidifier or dehumidifier into the controller's output socket.
  3. Sensor Placement: Position the 15-foot sensor where humidity control is needed for accurate readings.

Adjusting Humidity Levels

  1. Selecting Mode: Press and hold the knob for 3 seconds, then turn to select either Humidify or Dehumidify mode. Press the knob again to save the setting.
  2. Setting Day and Night Humidity: Click the knob to display "day" and set the desired day humidity level. Press the knob again to switch to "night" mode and set the night humidity level. Save the settings with another press.

Monitoring and Maintenance

  1. Regular Checks: Monitor the LED indicators to ensure the controller operates correctly, and the output is active when needed.
  2. Cleaning: Keep the sensor clean and free from dust or debris to maintain accurate readings.

The INNO-HUMCTRL Humidity Controller - The Protector is an advanced, reliable solution for managing indoor humidity levels. Its accurate sensor, day and night adjustments, and versatile operation modes ensure optimal conditions for plant growth and comfort. Easy to install and use, the INNO-HUMCTRL is a valuable addition to any indoor environment requiring precise humidity control.

Reviews

Average Star Rating:
0.00 (0 reviews Total)
  • 5 stars
    0
  • 4 stars
    0
  • 3 stars
    0
  • 2 stars
    0
  • 1 star
    0
Have you used the product?
Tell us something about it and help others make the right decision
Show reviews with:
5 stars (0 reviews)
4 stars (0 reviews)
3 stars (0 reviews)
2 stars (0 reviews)
1 star (0 reviews)

No reviews found